![]() There is an important distinction because the durso basically will always have water running through it (though in a bean animal it is very small amount), and as such it should not be treated the same as an emergency drain. I think you are calling the durso the 'first emergency'? Thanks.Ī bean animal is made up of 1 full siphon, 1 durso, and 1 dry emergency. I think I may be favoring this plumbing layout.Īny comments, insight, or tales from experience are greatly appreciated. Will this cause more noise than Design #1, or is it negligible?ĭesign #3 is similar to #1, but with first emergency durso drain (the one that may move some water) is tied directly to the main line primary full siphon piping. However, my concern here is the two 45* elbows. I like how this design looks under the main tank, despite the gate valve no longer being concealed. The main primary full siphon piping on the other hand has the gate valve just below the overflow, and then after the 60* elbow, the piping runs through two 45* elbows before hitting the double 90*. My only concern is the cross of the one emergency pipe over the main pipe (under the main tank) is messy and may be a pain if I were to have to repair something in the future.ĭesign #2 has the two emergencies durso and dry emergency drains coming down and over to their respective sump entry points without crossing over any other piping. ![]() As for the emergencies durso and dry emergency, there should be little to no water flowing through the first emergency durso drain, and nothing flowing through the second dry emergency if they were moving water, they would make a lot of noise, which would be the "alarm" that something is wrong. My logic for the main primary full siphon piping is to have the water flow as smooth as possible down to the sump and reduce noise. The two emergency durso and dry emergency drains both come down to 90* elbows, and through another 90* elbow down into the tank. I'm in between (3) layouts for the drain plumbing and I was looking for some feedback, please.ĭesign #1 has the main primary full siphon drain coming down from the overflow, turning 60* and through a gate valve (Spears' tech support says that the valve stem CAN be configured downward in this manner), down to a double 90* elbow, and finally to two 90* long sweep elbows and down into filter socks. Hello, I'm in the process of sketching out (or over engineering? lol) a 40G sump layout for a 125G tank with a Bean Animal overflow system. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |